1.Cantidaddeproductosporpaquete:6


Acerca de este artículo

  • Retrasos de tiempo ajustables de 3 segundos a 10 minutos
  • entrada de voltaje: 19-288VAC / VDC
  • Frecuencia de línea: 50/60Hz
  • Clasificaciones de salida: 40 mA ~ 1,5 A; Clasificaciones de salida de irrupción: 15 amperios
  • Paquete: 2 temporizadores de retardo



Descripción del producto

DQ-68
DQ-68
DQ-68
DQ-68

Steve Powell
Comentado en los Estados Unidos el 12 de febrero de 2025
Replaced both timers on overhead crane hoist controls. Took 5 minutes to synchronize the cut on adjustment between the two. Worked great. Better than the OEM
TS
Comentado en los Estados Unidos el 9 de enero de 2025
Using a 24VAC HVAC application, I attempted to use this to drive a 24VAC relay with a time delay. Pretty simple eh?Well there's a problem. While the time delay is in effect, the relay would buzz and sometimes randomly latch. Not good. Too much leakage voltage. Both units had the same problem. Tried adding various resistors in parallel with the relay to increase the current draw through the delay module thinking that it was under some minimum current threshold. Still buzzed. Still too much leakage in the delay state no matter what I tried.Low quality? Not good QA? Unsure. But rather than sending them back, I decided to try cutting the jumper wire that is supposed to be used to enable high voltage use. Well guess what? That solved the relay buzzing during the delay state, and it's been working perfectly ever since... for weeks so far, actuating many times per day. Time delay seems to be accurate as well based on the dial setting.So even though you aren't supposed to cut the jumper for lower voltage applications (ie: 24VAC), I'm going to recommend going off-script here if you detect too much leakage during the off/delay state with 24VAC. Can't say if this trick will work with lower voltages or DC. But it should work with 24VAC and higher.This workaround saved me the hassle of sending them back and sourcing a different module, possibly at a higher cost. I hope this helps someone. And I also hope the manufacturer of this delay module fixes this bug in a future update.
Earl Duskey
Comentado en los Estados Unidos el 15 de octubre de 2024
Installed and this have been very reliable so far.
Michael Sicard
Comentado en los Estados Unidos el 10 de octubre de 2024
The desire was to have a delay in starting a reverse osmosis system pressure pump for several minutes. This will permit the captive pressure tank to supply the flow and start the pump only when the full system pressure drops off. It works very well with the adjustable switch set to the 3 minute mark.
Robert Creamer
Comentado en los Estados Unidos el 29 de septiembre de 2024
Very easy to wire worked perfect